PWP Offer: Surgical Respirator R2 (12pcs) with 1 bottle of Anti-Bac Spray (only valid with any purchase made in eStore)


88 items left

With Protection Class of N95 . FFP2 NR . KN95, novita Surgical Respirators are produced through the best possible quality and standards. Tested by accredited testing laboratories in Singapore, U.S. and China, this ergonomically close facial fit and secure seal respirators are backed with proven filtration efficiency of ≥99.89% against 0.1 micron particle, ≥98.21% against oil aerosol, 99.95% against bacteria and passed the synthetic blood penetration test at 120 mmHg as per ASTM F1862-17 to meet the U.S NIOSH, EU and FDA Recognized Consensus Standards. Reducing inhalation exposure to harmful airborne contaminants and providing fluid resistance, novita Surgical Respirators are designed for maximum protection with breathable comfort for you and your loved ones!

novita Respirator The R Series is ergonomically designed with a close facial fit and secure seal to achieve 98.8% filtration efficiency against 0.3 micron particulates, airborne bacteria and virus. Composed of 4 and 5 ply of filter layers, it helps to reduce inhalation exposures to harmful airborne contaminants and provide effective protection with breathable comfort for you and your loved ones.

Air, the substance of life

Everyone should be concerned about the air around us since air pollutants can cause a variety of health problems and are especially harmful to young children, old folks and those with pre-existing respiratory conditions. The importance of air quality is obvious as we take in approximately 26,000 breaths, which is equivalent to about 800 oxygen tanks every day.

WHAT IS IN OUR AIR?

Air, the substance of life

Everyone should be concerned about the air around us since air pollutants can cause a variety of health problems and are especially harmful to young children, old folks and those with pre-existing respiratory conditions. The importance of air quality is obvious as we take in approximately 26,000 breaths, which is equivalent to about 800 oxygen tanks every day.

WHAT IS IN OUR AIR?

HAZE

The biggest hazard of the haze is the Particulate Matter PM2.5, which can be easily inhaled into our lungs arising to acute symptoms such as cough, wheezing, shortness of breath and a feeling of tiredness and weakness. Long-term exposure may lead to the development of underlying medical conditions.

BACTERIA

Pathogenic airborne bacteria could be responsible for a variety of respiratory infections and infectious diseases. These airborne bacteria gain access to the body’s tissues, commonly from mouth and nose and those with weaker immunity or with pre-existing medical conditions will be more susceptible to the invasion.

DUST

Dust particles are solids suspended in the air. The smaller the particle, the longer it will stay airborne. This would increase the likelihood of inhaling it into the respiratory passages and increase the risk of respiratory conditions.

HAZE

The biggest hazard of the haze is the Particulate Matter PM2.5, which can be easily inhaled into our lungs arising to acute symptoms such as cough, wheezing, shortness of breath and a feeling of tiredness and weakness. Long-term exposure may lead to the development of underlying medical conditions.

BACTERIA

Pathogenic airborne bacteria could be responsible for a variety of respiratory infections and infectious diseases. These airborne bacteria gain access to the body’s tissues, commonly from mouth and nose and those with weaker immunity or with pre-existing medical conditions will be more susceptible to the invasion.

DUST

Dust particles are solids suspended in the air. The smaller the particle, the longer it will stay airborne. This would increase the likelihood of inhaling it into the respiratory passages and increase the risk of respiratory conditions.

PROVEN FILTRATION PERFORMANCE

BACKED BY GLOBALLY ACCREDITED LABORATORIES

novita surgical Respirator r2 and r5 Certifications & TEST STANDARDS

Protection ClassTest StandardTesting BodiesCertifications
N95 Protection ClassNIOSH-42C FR84USA Accredited LabNIOSH Certification In Process
FDA Recognized Consensus StandardsASTM F2100-19Singapore Accredited LabASTM
FFP2 Protection ClassEN149:2001China Accredited LabCE Certified
KN95 certifiedGB2626-2006China Intertek-
FDA Recognized Consensus StandardsASTM F1862-17Singapore Accredited LabASTM

FILTRATION PERFORMANCE TEST

1

Inhalation &
Exhalation Resistance

Tested in accordance to 42 CFR Part 84.180, the air exchange differential was measured for the inhalation and exhalation resistance with NIOSH procedure. novita Surgical respirators have conformed to this NIOSH criterion for airflow resistance, ensuring wearer’s breathability comfort.

2

99.95% Bacterial
filtration efficiency

Tested in accordance to ASTM F2101-19, FDA Recognized Consensus Standards, novita Surgical Respirator is capable of retaining up to 99.95% of biological aerosol.

3

≥98.8% PARTICLE FILTRATION
EFFICIENCY for R2

Tested in accordance to KN95 GB2626-2006 standard, novita Surgical Respirator achieve 98.8% removal of PM0.3, surpassing the KN95 filtration efficiency requirement of ≥95%.

4

PM0.1 TO PM5.0 PARTICLE
FILTRATION EFFICIENCY

Tested by Singapore Accredited Lab, novita Surgical respirator attains remarkable filtration efficiency of up to 100% against a range of particle from PM0.1 to PM5.0 in size, providing you and your loved ones with maximum protection.

5

≥99.69% Particle (NaCl)
Filtration Efficiency For R5

Tested in accordance to EN149:2001+A1:2009 standard, novita Surgical Respirator R5 meets the FFP1, FFP2 and FFP3 requirement for Sodium Chlorine Test at 95 l/min with remarkable results as high as 99.84% filtration efficiency.

6

≥99.34% Particle (Parafin Oil)
Filtration Efficiency For R5

Tested in accordance to EN149:2001+A1:2009 standard, novita Surgical Respirator R5 meets the FFP1, FFP2 and FFP3 requirement for Paraffin oil test at 95 l/min with outstanding result as high as 99.77% filtration efficiency.

MATERIAL PROPERTIES TEST

5

Synthetic Blood
Penetration Test

ASTM F1862-17 Standard, the novita Surgical Respirator has passed the 120 mmHg high-velocity stream of synthetic blood fluid resistance test to provide complete protection with breathable comfort.

6

WATER
PROOFING TEST

The water-resistance non-woven cloth repels water droplet, aerosols and fluids and does not allow it to seep through to prevent droplet transmission.

7

Flammability
Test

Tested in accordance to ASTM F2100-19, novita Surgical Respirator material does not ignite and passed the Flammability Test requirements specified in 16 CFR Part 1610.

• Complete Protection • Quality Assurance
• High-Performance • Breathable Comfort

01. Water-resistance Non-Woven cloth
02 AND 03. ELECTROSTATIC DUPLEX MELT-BLOWN MATERIAL
04. HYPOALLERGENIC NON-WOVEN CLOTH

• Complete Protection • Quality Assurance
• High-Performance • Breathable Comfort

01. Water-resistance Non-Woven cloth
02. Moisture retention cotton
03 AND 04. Hi-performance ELECTROSTATIC DUPLEX MELT-BLOWN MATERIAL
05. HYPOALLERGENIC NON-WOVEN CLOTH

FEATURES

01. Adjustable nose bridge
02. DIY Nose Bridge Pad (Optional)
03. R2 4-ply or R5 5-Ply filter layer media
04. ultrasonic seam
05. Elastic ear band
06. Lightweight design
07. CLOSE FACIAL FIT

PUTTING ON YOUR surgical
Respirator R2 earband

Use the AB Spray to perform hand hygiene before putting on the surgical respirator.

Unfold the surgical respirator. Flatten the metal nose bridge then bend it into a contour.

Hold the surgical respirator by the ear loops. Place a loop around each ear.

Position the surgical respirator under your chin with the nose bridge up.

Using both hands, bend the metal nose bridge to fit snugly against your nose and face.

Perform a fit check. Place both hands completely over the surgical respirator. Exhale sharply to check for air leaks.

Use the AB Spray to perform hand hygiene before putting on the surgical respirator.

Unfold the surgical respirator. Flatten the metal nose bridge then bend it into a contour.

Hold the surgical respirator by the ear loops. Place a loop around each ear.

Position the surgical respirator under your chin with the nose bridge up.

Using both hands, bend the metal nose bridge to fit snugly against your nose and face.

Perform a fit check. Place both hands completely over the surgical respirator. Exhale sharply to check for air leaks.

PUTTING ON YOUR surgical
Respirator R2 headband

Use the AB Spray to perform hand hygiene before putting on the surgical respirator.

Unfold the surgical respirator. Flatten the metal nose bridge then bend it into a contour.

Slide your hands through the headbands and position the surgical respirator under your chin with metal nose bridge up.

Hold the surgical respirator in position, pull the top headband to rest it on the back of your head. Pull the bottom headband and rest it on your neck, below your ears.

Using both hands, position and bend the metal nose bridge to fit snugly against your nose and face.

Perform a fit check. Place both hands completely over the surgical respirator. Exhale sharply to check for air leaks.

Use the AB Spray to perform hand hygiene before putting on the surgical respirator.

Unfold the surgical respirator. Flatten the metal nose bridge then bend it into a contour.

Allow the upper headband to be hanging freely in front of the surgical respirator. Hold the lower edge of the surgical respirator and pull the lower headband over your head, adjust and rest it comfortably on your neck.

While holding onto the metal nose bridge, pull the upper headband over your head and secure it at the back of the head.

Using both hands, position and bend the metal nose bridge to fit snugly against your nose and face.

Perform a fit check. Place both hands completely over the surgical respirator. Exhale sharply to check for air leaks.

DIY NOSE BRIDGE
PAD wearing guide

Flip the surgical respirator inside out. Align the adhesive onto the nose bridge area. Paste it on as per illustrated.

LEARN MORE

SURGICAL RESPIRATOR R2 /R5 EARBAND

SURGICAL RESPIRATOR R2 / R5 HEADBAND

DIY NOSE BRIDGE
PAD wearing guide

Flip the surgical respirator inside out. Align the adhesive onto the nose bridge area. Paste it on as per illustrated.

LEARN MORE

SURGICAL RESPIRATOR R2 / R5
EARBAND

SURGICAL RESPIRATOR R2 / R5
HEADBAND

PRODUCTION FACILITY & PROCESSES

Conformity to Quality Management System (QMS): ISO13485

Greatly pride to be a Health Science Authority of Singapore Class A medical device manufacturer license holder (no. ES0501000), our high-speed fully automated production facility and processes are in conformity to Quality Management System (QMS): ISO13485.

Adhered to the stringent quality and production controls, we provide assurance for the best possible surgical respirators’ quality and standard.

Quality Assurance. Product Consistency. Proven Efficiency

PROUDLY MADE IN SINGAPORE

SURGICAL RESPIRATOR the R Series

8-piece / 12-piece / 100-piece

R2 (earband | headband)

Equipped with protection class N95 & KN95, novita Surgical Respirator R2 is composed of 4-ply filter layers to achieve ≥98.79% filtration efficiency against 0.3 micron particle and 99.95% filtration efficiency against bacteria. Qualified as Surgical Respirator, it passed the ASTM F1862-17 Level 2 Standard to proof its effective protection for medical purpose by reducing inhalation exposure to harmful airborne contaminants and disease transmission. Available in both earband and headband options wearer selection.

R5 (earband | headband)

CE certified, novita Surgical Respirator R5 is graded with a protection class of FFP2 NR. Comes in earband or headband option, R5 is composed of 5-ply filter which includes a Hi-Performance Electrostatic Melt-Blown Material to achieve effective filtration of ≥99.89% filtration efficiency against 0.1 micron particle, ≥99.21% against oil aerosol and 99.95% filtration efficiency against bacteria. Qualified as a Surgical Respirator, this medical-use respirator passes the ASTM F1862-17 Level 2 Standard to prove its effective protection for medical purpose, preventing infectious diseases transmission for complete protection and quality assurance.

*Note: Fastener is only available for surgical respirator R5 earband.

For corporate enquiry, please email to corporate@novita.com.sg